Filter Quality and Oil Analysis

"How does the quality of a filter impact oil analysis results (contamination and ferrous wear)? Is it correct to say that using filters with different beta ratios in same equipment will result in different analysis results? Is there any correlation in setting alarm levels and filter beta ratio?"

The quality of the filter is directly proportional to the cleanliness and wear rate of the system. The higher the beta for the same micron pore size will result in a faster cleanup rate; thus, it is better able to control ingression of solids in the system. The main system ingression sources typically are seals, breathers and oil top-ups, and wear debris. When catalytic wear metals are removed from the oil, the lubricant will experience longer oxidative life.

Therefore, expect to see better cleanliness results on the hard particle measurements, as well as lower levels of wear debris in the system, assuming that the oil is in good condition and there are no other problems like water ingress or misalignment or imbalance.

In terms of setting alarm levels, the first step is to set the alarm levels to achieve a reasonable and realistic gain in lubricant and machine life. Using any of several methods, this can be done to optimize your requirements based on financial, safety, environmental and reliability goals.

On that basis, the appropriate filter can be selected. Most filter manufacturers have methods to determine the required element size and pore rating to not only meet the cleanliness target, but also to match the lubricant viscosities at operating temperature that would affect the flow rate. Most companies have established a beta ratio of 200 for their quoted pore size, although recent changes mean that they must also quote a beta value for a number of size ranges to establish performance. (See this article for more information.)

Over the life of the machine, a better-quality filter (generally more expensive) will prove to be more cost-effective than a cheaper filter owing to the relationship between filter performance and the system wear rates. To add value to that, many high-performance filters offer an associated improved dirt-holding capacity.


Reservoir Baffles and Settling Zones

Baffles are used to prevent fluid just returned to the tank from passing directly back to the pump inlet. For a number of reasons, a longer transit path is considered beneficial; it encourages better heat conduction from the fluid, better contamination and air separation, and better mixing with the bulk fluid. This is usually accomplished by separating the inlet and outline by as long of a flow path as feasible.

Submit your tip.


Effective Contamination Control Training

It could be the biggest cost-reduction opportunity at your facility. Systematically reducing lubricant contamination levels extends machine and lubricant life by up to 10X.

By implementing just a few of the techniques you learn in this course, you could easily double or even triple oil and machine life at your facilities.

Join Noria's Jim Fitch at his three-day training course Effective Contamination Control coming to Minneapolis, MN on April 4-6.


Preventative Measures Make Sense

Catastrophic pump failure on circulating and hydraulic systems can damage more than just the pump. Consider using oil strainers or filters upstream of all equipment components to prevent pump failure debris from damaging these machines. This is also important for kidney-loop systems with expensive heaters and oil/water separators. (Submitted by Rodger Shaffer, Senior Manufacturing Engineer, Timken Latrobe Steel. Thanks Rodger!)

Submit your tip.

Resources

 

PdMA
Excellence in
Lubricant Analysis
We provide a wide range of testing on oil, grease, fuel and transformer oil. Standard testing results available 24 to 48 hours from receipt of samples.

 

PdMA
INTERNORMEN's
CCM 01
High value particle counter with laser sensor for reliable inline monitoring of contamination classes. Data storage and transfer to PC possible.
E-mail

 


PdMA

Increase machinery productivity
and prevent unscheduled downtime with Kleentek Varnish Removal Systems.
Kleentek
1-800-252-4647
www.kleentek.com

 

Lubrication Excellence/Reliability World 2006
Lubrication Excellence 2006 Program
Download full conference details here. May 16-18, 2006, Columbus, OH

 

 

Training Calendar

MARCH 2006

Machinery Lubrication I
7-9 Houston, TX
6-7 Antofagasta, Chile
7-8 Gdansk, Poland
7-8 Mexico D.F., Mexico
7-9 Point Lisas, Traindad
14-15 Midrand, South Africa
21-23 Sydney, Australia
28-29 Mendoza, Argentina

Análisis de Aceite para Equipo Móvil
15-16 Madrid, Spain

Contamination Control Basics
27 Midrand, South Africa

Effective Contamination Control
14-15 Nijmegen, Netherlands
21-23 Point Lisas, Trinidad

Machinery Lubrication Basics
23 Nijmegen, Netherlands

Machinery Lubrication II
8-9 Angofagasta, Chile
9-10 México D.F., México

Oil Analysis I
20-21 Barcelona, Spain
21-23 Calgary, Canada
28-30 Sydney, Australia

Oil Analysis II
2-3 Midrand, South Africa
22-23 Barcelona, Spain

Oil Analysis for Maintenance Professionals
22-24 Gdansk, Poland

APRIL 2006

Machinery Lubrication I
3-4 Santiago, Chile
4-6 Melbourne, Australia
11-12 Amsterdam, Netherland
11-13 Daegu, Korea
17-18 Lima, Peru
25-27 Pittsburgh, PA

Effective Plant Reliability Management
25-26 Pittsburgh, PA

Contamination Control Basics
7 Midrand, South Africa

Effective Contamination Control
4-6 Minneapolis, MN

Machinery Lubrication II
3-4 Midrand, South Africa
4-5 Gdansk, Poland
5-6 Santiago, Chile
19-20 Lima, Peru
25-26 Maracaibo, Venezuela
25-26 Mendoza, Argentina

Mantenimiento Proactivo y Analysis de Aceite I
25-26 Quito, Ecuador

Oil Analysis I
24-26 Petaling Jaya, Malaysia
25-26 Amsterdam, Netherlands
25-26 Santa Cruz, Bolivia
26-28 São Paulo, Brazil

Oil Analysis II
4-6 Monterrey, N.L., México
18-20 Point Lisas, Trinidad

Técnicas de Lubricación
24 Maracaibo, Venezuela

Filtration Tips is published twice a month by:
Noria Corporation, 1328 E. 43rd Court, Tulsa, OK 74105 USA. (918) 749-1400

Because results will vary widely based on a number of factors, Noria Corporation cannot warrant the results of any information within this e-mail.

© 2006 Noria Corporation

»Receive your own subscription to Filtration Tips

Other Resources:
»Archives
»
Reliable Plant Magazine
»Machinery Lubrication Magazine
»Practicing Oil Analysis Magazine
»Bookstore
»Buyers Guide
»Dictionary